Remove motor/tank cover assembly and hold level.ģ. Be sure there are no kinks in the line that would inhibit flow.Ģ. Clean the tank with warm water and mild soap.Ĥ. Make certain that the unit is disconnected from the power source before attempting to service or remove any component.Ģ. If it is not possible to slope discharge line down, make an inverted “U” trap directly above the pump at the highest point.ġ. This will give a siphoning effect which will improve efficiency of the condensate unit and will, in most cases, eliminate the need for a check valve (Figure 5). From this high point, slope discharge line down slightly to a point above drain area then turn down and extend to a point below or approximately level with the bottom of the condensate unit. Do not extend this line above the head/GPH of the particular model being installed. From condensate unit, extend discharge piping straight up as high as necessary. maximum to prevent excessive flow back to unit). ![]() The outlet piping should be flexible tubing secured with a hose clamp (not provided) or pipe (3/8" I.D. ![]() Be sure that the inlet piping is cut at an angle where it enters the tank.Ģ. Extend the inlet piping into the tank from 1 to 3 inches to ensure that it will not interfere with proper float operation. Be sure inlet piping is sloped downward to allow gravity flow (Figure 4). Run flexible tubing or pipe from evaporator drain into one of the three pump inlets. Typical hook-up of NC circuits would be (Figures 2 and 3).ġ. The safety switch comes from the factory with leads connected to the COM and NO switch terminals. The COM and NC switch contacts may be used to actuate a low voltage alarm circuit (connected in series) if the heating/cooling system cannot be disrupted. To control a thermostatic circuit the COM and NO connections from the safety switch are to be wired in series with the low voltage thermostat circuit to shut down the heating/AC circuit. Safety switch: The safety overflow switch should be connected to a Class II low voltage circuit. If power cord does not have a plug, wiring is as follows: green (or green/yellow) - ground black (or brown) - line white (or blue) - neutral.ģ. Power cord must be connected to a constant source of power (not a fan or other device that runs intermittently). Line voltage: Connect power cord to line voltage specified All wiring must comply with local codes.Ģ. Shut off electrical power at fuse box before making any connections. FAILURE TO DO SO MAY CAUSE PIPING TO BREAK, PUMP TO FAIL, MOTOR BEARING FAILURES, ETC.ġ. SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND WHEN INSTALLED. IN ANY INSTALLATIONS WHERE PROPERTY DAMAGE AND/OR PERSONAL INJURY MIGHT RESULT FROM AN INOPERATIVE OR LEAKING PUMP DUE TO POWER OUTAGES, DISCHARGE LINE BLOCKAGE, OR ANY OTHER REASON, A BACKUP SYSTEM(S) AND/OR ALARM SHOULD BE USED. TO REDUCE THE RISK OF ELECTRICAL SHOCK, BE CERTAIN THAT IT IS CONNECTED TO A PROPERLY GROUNDED GROUNDING-TYPE RECEPTACLE. THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND/OR GROUNDING-TYPE ATTACHMENT PLUG. PUMP SHOULD BE USED WITH LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS.ĭO NOT HANDLE PUMP WITH WET HANDS OR WHEN STANDING ON A WET OR DAMP SURFACE, OR IN WATER. INSTALLATION AND CONNECTIONS ARE TO BE MADE BY A QUALIFIED PERSON.ĭO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. KNOW THE PUMP APPLICATION, LIMITATIONS AND POTENTIAL HAZARDS. READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE Ferguson PUMP. They will assist you in replacement or repair, if required. If damage has occurred, make notation and notify the firm that you purchased the pump from. When you receive your pump, examine it carefully to determine that there are no broken or damaged parts that may have occurred during shipment. The Ferguson pumps are carefully packaged, inspected and tested to ensure safe operation and delivery. It has been engineered to give you long and trouble-free service. ![]() The Ferguson unit you have purchased is of the highest quality workmanship and material. The pump is controlled by a float/switch mechanism which turns the pump on when approximately 2-1/4" of water collects in the tank, and automatically switches off when the tank drains to approximately 1-1/4". ![]() Your Ferguson condensate pump is designed as an automatic condensate removal pump for water dripping off an air conditioner evaporative coil.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |